javascript
---------------- Javascript Base ----------------
bootstrap5 - SET
bootstrap5 - SET
---------------- Javascript Base ----------------
main
navigation
ShiftBulk
wrassepinnedissue


javascript_special
---------------- Javascript Special Requirements ----------------
handlebars
alpaca
highcharts
cropper
mathjs
jsoneditor
leaflet
---------------- Javascript Special Requirements ----------------
modification_btn
docs

messages
shoppingcart
datatablesearch

Navigation
docs_nav



flatprojectmap.handlebars
Drive System Details
modificationbutton
5bb307d1e8e8092114aea6f9
docs_htmltables.handlebars

Belt conveyor installations are governed primarily by their height and length (which are invariably unique), and as such are generally built from individual parts. The items in this section are grouped design parameters for drive systems used on this site.


docs_datatable.handlebars
Full Load Speed (r/min) Drive Friction Factor - Secondary Drive Friction Factor - Primary θ (Secondary) (Degree) θ (Primary) (Degree) Drive Ratio Number of Powerpacks on Primary Number of Pulleys c/w Powerpack Standard Number of Poles Starting Factor Frame Height Electric Motor Inertia (kg. m²) Motor FOS Power Factor - cos φ ηdrive ηred ηcpig Drive Starting Method Installed Gear Ratio Unit Installed Power (kW) Total Powerpacks Installed
1
0.35
0.35
200
200
2
2
2
IE3 (Premium Efficiency)
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
20
250
3
0.35
200
1
1
1
IE3 (Premium Efficiency)
4
1.6
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
20
75
1
0.35
0.35
210
210
2
2
2
IE3 (Premium Efficiency)
4
1.6
AC Induction Motor with Variable Frequency Control and Direct Coupling
17.1
500
3
.35
.35
0
210
1
2
1
IE3 (Premium Efficiency)
4
1.6
AC Induction Motor with Variable Frequency Control and Direct Coupling
16
315
2
0.35
0.35
0
200
1
2
1
4
1.6
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
20.9
90
2
.35
.35
0
210
1
1
1
IE3 (Premium Efficiency)
4
1.6
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
18
55
1
1485
0.35
0.35
270
270
1
2
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
1.21013
1.2
0.78
0.954
0.97
0.98
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
28.78
55
2
1489
0.35
0.35
0
220
1
1
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
25.13342
1.2
0.8
97
0.97
0.98
AC Induction Motor with Variable Frequency Control and Direct Coupling
25.421
630
1
1490
0.35
0.35
200
200
2
2
2
IE3 (Premium Efficiency)
4
1.6
Superior Frame
7.33813
1.2
0.8
97
0.97
0.98
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
16
220
3
1485
0.35
0.35
200
200
1
1
1
IE3 (Premium Efficiency)
4
1.6
Reduced Frame
3.24774
1.2
0.8
96
0.97
0.98
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
20
110
1
1490
0.35
0.35
200
200
1
1
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
3.98762
1.2
0.8
96
0.97
0.98
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
20
160
1
1490
0.35
0.35
200
200
1
1
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
3.79211
1.2
0.9
96
0.97
0.98
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
20
132
1
1490
0.35
0.35
0
200
1
1
1
IE3 (Premium Efficiency)
4
1.6
Superior Frame
7.69609
1.2
0.8
97
0.97
0.97
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
16
250
1
1488
0.35
0.35
200
200
1
1
2
IE3 (Premium Efficiency)
4
1.6
Standard Frame
22.14135
1.2
0.8
97
0.955
0.96
AC Induction Motor with Variable Frequency Control and Direct Coupling (VFD)
17.1
560
2
1490
0.35
0.35
200
200
1
1
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
2.89325
1.2
0.8
96
0.955
0.96
AC Induction Motor with Variable Frequency Control and Direct Coupling (VFD)
20
110
1
1488
0.35
0.35
200
200
1
1
2
IE3 (Premium Efficiency)
4
1.6
Standard Frame
22.14135
1.2
0.8
97
0.955
0.96
AC Induction Motor with Variable Frequency Control and Direct Coupling (VFD)
20
560
2
1485
0.35
0.35
200
200
1
1
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
2.0877
1.2
0.8
95
0.955
0.96
AC Induction Motor with Variable Frequency Control and Direct Coupling (VFD)
20
75
1
1488
0.35
0.35
200
200
2
2
2
IE3 (Premium Efficiency)
4
1.6
Standard Frame
22.14135
1.2
0.8
97
0.955
0.96
AC Induction Motor with Variable Frequency Control and Direct Coupling (VFD)
17.1
560
3
1485
0.35
0.35
200
200
2
2
2
IE3 (Premium Efficiency)
4
1.6
Standard Frame
6.72567
1.2
0.8
96
0.955
0.96
AC Induction Motor with Variable Frequency Control and Direct Coupling (VFD)
14
315
3
1490
0.35
0.35
200
200
1
1
1
IE3 (Premium Efficiency)
4
1.6
Superior Frame
7.33813
1.2
0.8
97
0.955
0.96
AC Induction Motor with Variable Frequency Control and Direct Coupling (VFD)
14
220
1
1489
0.35
0.35
200
200
2
2
2
IE3 (Premium Efficiency)
4
1.6
Standard Frame
13.79477
1.2
0.9
96
0.955
0.96
AC Induction Motor with Variable Frequency Control and Direct Coupling (VFD)
20
400
3
1488
0.35
0.35
200
200
1
1
2
IE3 (Premium Efficiency)
4
1.6
Standard Frame
22.14135
1.2
0.8
97
0.955
0.96
AC Induction Motor with Variable Frequency Control and Direct Coupling (VFD)
17.1
560
2
1485
0.35
0.35
200
200
1
1
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
2.16516
1.2
0.8
95
0.955
0.96
AC Induction Motor with Variable Frequency Control and Direct Coupling (VFD)
16
90
1
1480
0.35
0.35
210
210
1
1
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
1.04981
1.2
0.8
95
0.955
0.98
AC Induction Motor with Full Voltage Starting and Direct Couplings
35.5
55
1
1470
0.35
0.35
210
210
1
1
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
0.20974
1.2
0.8
93
0.97
0.97
AC Induction Motor with Variable Frequency Control and Direct Coupling (VFD)
31.5
22
1
1490
0.35
0.35
210
210
1
1
2
IE3 (Premium Efficiency)
4
1.6
Standard Frame
3.79211
1.2
0.8
96
0.97
0.97
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
20
132
2
1490
0.35
0.35
210
210
1
1
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
5.74661
1.2
0.8
96
0.97
0.97
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
16
250
1
1490
0.35
0.35
210
210
1
1
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
3.79211
1.2
0.8
96
0.97
0.97
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
22.4
132
1
1490
0.35
0.35
0
210
1
2
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
5.74661
1.2
0.8
96
0.97
0.98
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
14
250
2
1490
0.35
0.35
0
210
1
2
1
IE3 (Premium Efficiency)
4
1.6
Standard Frame
2.89325
1.2
0.8
96
0.97
0.98
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
14
110
2
1470
0.35
0.35
210
1
1
1
IE3 (Premium Efficiency)
4
3
Standard Frame
0.20974
1.2
0.8
93
0.97
0.98
AC Induction Motor with Full Voltage Starting and Direct Couplings
14
22
1
1445
0.35
0.35
0
200
1
1
1
IE3 (Premium Efficiency)
4
3
Standard Frame
0.00655
1.2
0.7
86
0.97
0.98
AC Induction Motor with Full Voltage Starting and Direct Couplings
169
1.5
1
1775
0.35
0.35
180
180
1
2
1
IE3 (Premium Efficiency)
3
1.6
Standard Frame
3.775
1.2
0.9
96
0.97
0.97
AC Induction Motor with Full Voltage Starting and Fixed Fill Fluid Coupling
24.202
150
2


searchflatarrary.handlebars


wrasseform.handlebars

childType : 5bb4401ce8e8092114aea701
elementID : 5bb307d1e8e8092114aea6f9
modal1
modal2
modal3
docs_javascript

shortcut_edit

ShiftBulk

A platform developed to streamline conveyor system design, procurement, and maintenance in mining operations. Beta 1.0.0

Built with the Fraternate user framework

Sign up to get started!

Sign up

Site Details
Issues
Terms and Conditions
Collaborate

If you are interested in collaborating on an activity or project, we welcome you to reach out to us.

footer
© 2024 ShiftBulk